Energy meters – DME
Single-phase direct connection

DMED110T1
Impulse output
Impulse output
| DMED110T1 | |
|---|---|
| INSTALLATION | |
| Type | energy meter |
| Connection | single-phase |
| Switching | direct 40A |
| INTEGRATED INTERFACES | |
| RS485 | – |
| Static digital outputs | 1 |
| Digital inputs | – |
| COMMUNICATION EXPANSIONS | |
| RS485 | – |
| Ethernet | – |
| Gateway RS485-Ethernet | – |
| Gateway RS485-Modem3G | – |
| Gateway RS485-Modem4G | EXCM4G01 |
| INPUT/OUTPUT EXPANSIONS | |
| 2 digital inputs + 2 static outputs | – |
| 2 digital inputs + 2 5A/250VAC outputs | – |
| 4 digital inputs + 2 5A/250VAC outputs | – |
| SPECIAL FUNCTIONS | |
| Data loggers | – |
| OTHER CHARACTERISTICS | |
| Gateway function1 | – |
| THD measurement | – |
| Analysis of harmonics | – |
| Programmable alarms | |
| Energy counting | |
| Hour counter | |
| SPECIAL VERSIONS | MID |
Notes
1 Gateway function: converts signals from an RS485 network to Ethernet (maximum 10 concatenated devices)
NB
For an up-to-date list of expansion modules, visit www.lovatoelectric.com

DMED111
RS485
RS485
| DMED111 | |
|---|---|
| INSTALLATION | |
| Type | energy meter |
| Connection | single-phase |
| Switching | direct 40A |
| INTEGRATED INTERFACES | |
| RS485 | |
| Static digital outputs | 1 |
| Digital inputs | – |
| COMMUNICATION EXPANSIONS | |
| RS485 | integrated |
| Ethernet | – |
| Gateway RS485-Ethernet | EXCCON01 |
| Gateway RS485-Modem4G | EXCM4G01 |
| INPUT/OUTPUT EXPANSIONS | |
| 2 digital inputs + 2 static outputs | – |
| 2 digital inputs + 2 5A/250VAC outputs | – |
| 4 digital inputs + 2 5A/250VAC outputs | – |
| SPECIAL FUNCTIONS | |
| Data loggers | – |
| Energy quality (EN50160) | – |
| OTHER CHARACTERISTICS | |
| Gateway function1 | – |
| THD measurement | – |
| Analysis of harmonics | – |
| Programmable alarms | – |
| Energy counting | |
| Hour counter | |
| SPECIAL VERSIONS | MID |
Notes
1 Gateway function: converts signals from an RS485 network to Ethernet (maximum 10 concatenated devices)
NB
For an up-to-date list of expansion modules, visit www.lovatoelectric.com

DMED121
RS485
RS485
| DMED121 | |
|---|---|
| INSTALLATION | |
| Type | energy meter |
| Connection | single-phase |
| Switching | direct 63A |
| INTEGRATED INTERFACES | |
| RS485 | |
| Static digital outputs | – |
| Digital inputs | – |
| COMMUNICATION EXPANSIONS | |
| RS485 | integrated |
| Ethernet | – |
| GMS/GPRS | – |
| Gateway RS485-Ethernet | EXCCON01 |
| Gateway RS485 Modem4G | EXCM4G01 |
| ADDITIONAL INPUTS/OUTPUTS | |
| 2 digital inputs + 2 static outputs | – |
| 2 digital inputs + 2 5A/250VAC outputs | – |
| 4 digital inputs + 2 5A/250VAC outputs | – |
| 2 analog inputs | – |
| SPECIAL FUNCTIONS | |
| Data loggers | – |
| Energy quality (EN50160) | – |
| OTHER CHARACTERISTICS | |
| Gateway function1 | – |
| THD measurement | – |
| Analysis of harmonics | – |
| Programmable alarms | – |
| Energy counting | |
| Hour counter | |
| SPECIAL VERSIONS |
Notes
1 Gateway function: converts signals from an RS485 network to Ethernet (maximum 10 concatenated devices)
2 DMED330: three single-phase loads can be monitored separately, with energy and hour counts per phase
NB
For an up-to-date list of expansion modules, visit www.lovatoelectric.com
Three-phase direct connection

DMED300T2
Integrated impulse output
Integrated impulse output
| DMED300T2 | |
|---|---|
| INSTALLATION | |
| Type | energy meter |
| Connection | three-phase |
| Switching | direct 63A |
| INTEGRATED INTERFACES | |
| RS485 | – |
| Static digital outputs | 2 |
| Digital inputs | 1 |
| COMMUNICATION EXPANSIONS | |
| RS485 | – |
| Ethernet | – |
| Gateway RS485-Ethernet | – |
| Gateway RS485/Modem3G | – |
| Gateway RS485/Modem4G | EXCM4G01 |
| INPUT/OUTPUT EXPANSIONS | |
| 2 digital inputs + 2 static outputs | – |
| 2 digital inputs + 2 5A/250VAC outputs | – |
| 4 digital inputs + 2 5A/250VAC outputs | – |
| SPECIAL EXPANSIONS | |
| Data-logger | – |
| OTHER CHARACTERISTICS | |
| Gateway function1 | – |
| THD measurement | – |
| Analysis of harmonics | – |
| Programmable alarms | |
| Energy counting | |
| Hour counter | |
| SPECIAL VERSIONS | – MID – UTF |
Note
1 Gateway function: converts signals from an RS485 network to Ethernet (maximum 10 concatenated devices)
NB
For an up-to-date list of expansion modules, visit www.lovatoelectric.com

DMED301
With built-in RS485
With RS485 integrated
| DMED301 | |
|---|---|
| INSTALLATION | |
| Type | energy meter |
| Connection | three-phase |
| Switching | direct 80A |
| INTEGRATED INTERFACES | |
| RS485 | |
| Static digital outputs | – |
| Digital inputs | 1 |
| COMMUNICATION EXPANSIONS | |
| RS485 | integrated |
| Ethernet | – |
| Gateway RS485-Ethernet | EXCCON01 |
| Gateway RS485/Modem4G | EXCM4G01 |
| INPUT/OUTPUT EXPANSIONS | |
| 2 digital inputs + 2 static outputs | – |
| 2 digital inputs + 2 5A/250VAC outputs | – |
| 4 digital inputs + 2 5A/250VAC outputs | – |
| SPECIAL FUNCTIONS | |
| Data-logger | – |
| OTHER CHARACTERISTICS | |
| Gateway function1 | – |
| THD measurement | – |
| Analysis of harmonics | – |
| Programmable alarms | |
| Energy counting | three + single-phase² |
| Hour counter | three + single-phase² |
| SPECIAL VERSIONS | – |
Note
1 Gateway function: converts signals from an RS485 network to Ethernet (maximum 10 concatenated devices)
NB
For an up-to-date list of expansion modules, visit www.lovatoelectric.com
Three-phase connection with CT

DMED310T2
Integrated impulse output, expandable
Integrated impulse output, expandable
| DMED310T2 | |
|---|---|
| INSTALLATION | |
| Type | energy meter |
| Connection | three-phase and single-phase |
| Switching | CT |
| INTEGRATED INTERFACES | |
| RS485 | – |
| Static digital outputs | 2 |
| Digital inputs | 1 |
| COMMUNICATION EXPANSIONS | |
| RS485 | EXM1012 |
| Ethernet | EXM1013 |
| Gateway RS485-Ethernet | – |
| Gateway RS485/Modem4G | EXCM4G01 + EXM1012 |
| INPUT/OUTPUT EXPANSIONS | |
| 2 digital inputs + 2 static outputs | EXM1000 |
| 2 digital inputs + 2 5A/250VAC outputs | EXM1001 |
| 4 digital inputs + 2 5A/250VAC outputs | – |
| SPECIAL EXPANSIONS | |
| Data-logger | EXM1030 |
| OTHER CHARACTERISTICS | |
| Gateway function1 | – |
| THD measurement | – |
| Analysis of harmonics | – |
| Programmable alarms | |
| Energy counting | |
| Hour counter | |
| SPECIAL VERSIONS | – MID – UTF with CT up to 3,000A |
Notes
1 Gateway function: converts signals from an RS485 network to Ethernet (maximum 10 concatenated devices)
NB
For an up-to-date list of expansion modules, visit www.lovatoelectric.com

DMED330
With built-in RS485
With RS485 integrated
| DMED330 | |
|---|---|
| INSTALLATION | |
| Type | energy² meter |
| Connection | three + single-phase |
| Switching | CT |
| INTEGRATED INTERFACES | |
| RS485 | |
| Static digital outputs | – |
| Digital inputs | – |
| COMMUNICATION EXPANSIONS | |
| RS485 | integrated |
| Ethernet | – |
| GMS/GPRS | – |
| Gateway RS485-Ethernet | EXCCON01 |
| Gateway RS485 Modem4G | EXCM4G01 |
| ADDITIONAL INPUTS/OUTPUTS | |
| 2 digital inputs + 2 static outputs | – |
| 2 digital inputs + 2 5A/250VAC outputs | – |
| 4 digital inputs + 2 5A/250VAC outputs | – |
| 2 analog inputs | – |
| SPECIAL FUNCTIONS | |
| Data loggers | – |
| Energy quality (EN50160) | – |
| OTHER CHARACTERISTICS | |
| Gateway function1 | – |
| THD measurement | – |
| Analysis of harmonics | – |
| Programmable alarms | – |
| Energy counting | three + single-phase² |
| Hour counter | three + single-phase² |
Notes
1 Gateway function: converts signals from an RS485 network to Ethernet (maximum 10 concatenated devices)
2 DMED330: three single-phase loads can be monitored separately, with energy and hour counts per phase
NB
For an up-to-date list of expansion modules, visit www.lovatoelectric.com
Impulse concentrator

DMECD
Impulse/signals concentrator
Impulse/signals concentrator
| DMECD | |
|---|---|
| INSTALLATION | |
| Type | data concentrator pulse counter |
| Connection | |
| Switching | |
| INTEGRATED INTERFACES | |
| RS485 | |
| Static digital outputs | – |
| Digital inputs | 8 (expandable to 14) |
| COMMUNICATION EXPANSIONS | |
| RS485 | integrated |
| Ethernet | EXM1013 |
| Gateway RS485-Ethernet | – |
| Gateway RS485/Modem4G | EXCM4G01 |
| INPUT/OUTPUT EXPANSIONS | |
| 2 digital inputs + 2 static outputs | EXM1000 |
| 2 digital inputs + 2 5A/250VAC outputs | EXM1001 |
| 4 digital inputs + 2 5A/250VAC outputs | EXM1002 |
| SPECIAL EXPANSIONS | |
| Data-logger | EXM1030 |
| OTHER CHARACTERISTICS | |
| Gateway function1 | |
| THD measurement | – |
| Analysis of harmonics | – |
| Programmable alarms | – |
| Energy counting | – |
| Hour counter | – |
| SPECIAL VERSIONS | – |
Notes
1 Gateway function: converts signals from an RS485 network to Ethernet (maximum 10 concatenated devices)
NB
For an up-to-date list of expansion modules, visit www.lovatoelectric.com